Industrial - Amplifiers
Model Number Emitter Cooling Eb,kV Ib,A Po (kW) Comment
Oxide Air 7.5 9.2 46
Oxide Air 6.5 25.5 112
Oxide Air 3.5 2.5 6
Thoriated Water 5 0.8 2.7
Thoriated Water 7 4 21
Thoriated Water 7 4 21
3CW2000A7 Oxide Water 4 1 2.6
Oxide Water 3 1 1.5
3CW30,000A7 Thoriated Water 11.5 5 45
Thoriated Water 11.5 5 45
Thoriated Water 10 7 60
Thoriated Water 12 7.7 76
Thoriated Water 4.9 2.2 7.5
3CW5000H7 Thoriated Water 4.9 2.2 7.5
3CW7000A7/YC-237 Thoriated Water 4.9 2.2 7.5
Thoriated Water 4.9 2.2 7.5
Thoriated Air 7.6 3.7 22.5
Thoriated Air 3.5 0.6 1.4
Thoriated Air 3.6 0.7 1.5
Thoriated Air 4 0.6 1.6
Thoriated Air 4 0.6 1.6
Thoriated Air 7 5.9 29
Oxide Air 4 1 2.5
Thoriated Air 7.8 5.7 31
3CX20,000C7 Thoriated Air 7.8 5.7 31
Thoriated Air 4.8 1.5 5.5
Thoriated Air 4.8 1.5 5.5
Thoriated Air 5.7 2.5 10
Thoriated Multi-Phase 24 182 2800
Thoriated Vapor 17.5 11.8 168
Thoriated Vapor 15 11.7 140
4CV250,000B Thoriated Vapor 19 32.5 460
Thoriated Vapor 15 11.5 137
Thoriated Water 7.5 2.8 16
Thoriated Water 19 10 165
Thoriated Water 20 15.2 220
Thoriated Water 20 15.2 220
Thoriated Water 10 4.5 36.5
4CW250,000B Thoriated Water 19 32.5 460
4CW30,000B Thoriated Water 12 4.5 28.2
Thoriated Water 15 11.5 137
Thoriated Air 7.5 3.2 16
Thoriated Air 10 4.6 36.5
Thoriated Air 5 0.9 2.5
Thoriated Air 11 5 28.2
Thoriated Air 7 1.9 11
Thoriated Air 19 7 55
Thoriated Air 7.5 2.8 12.5
Thoriated Water 21 59 1025
Thoriated Water 21.5 125 2158
Thoriated Water 12 2.1 18 *See footnote below
Thoriated Air 12 2.1 18 *See footnote below
All product data sheets are in PDF format. To read and print PDF files, download Adobe Acrobat Reader
Footnotes:
* The following Eimac types currently in production are for renewal use and are not suggested for new equipment design. Data on these tubes may be obtained from CPI MPP Division, Eimac Operation Application Engineering Department.